Dell PowerEdge 1655MC Manuel complémentaire - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel complémentaire pour {nom_de_la_catégorie} Dell PowerEdge 1655MC. Dell PowerEdge 1655MC 24 pages. Removing a fan
Également pour Dell PowerEdge 1655MC : Manuel du matériel (10 pages), Manuel du matériel (14 pages)
F i g u r e 1 - 1 .
Tu r n i n g O f f t h e S e r v e r M o d u l e
Verifying the Hard-Drive Mirroring Mode
Ensure that the server module is turned on. See Figure 1-1.
1
Monitor the POST progress.
2
When the POST reaches the PERC 4/im, either one or two SCSI drives are listed with
their IDs (nonmirrored mode) or one SCSI drive is listed as a virtual disk (mirrored
mode).
The following is an example of the display if there are two drives installed in
nonmirrored mode. If this display is seen during POST, proceed to "Turning Off the
Server Module" and then "Replacing the Server Module Board."
HBA
ID
LUN
VENDOR PRODUCT
0
0
0
Fujitsu MAN3184MP
0
1
0
Fujitsu MAN3184MP
0
7
0
LSI Logic 1020/1030
NOTE: Only one drive is listed if only one drive is installed in the server module.
power indicator
power button
REV
SYNC
5507
160.0
5A01
160.0
1000c00
320.0
Re plac ing the Se r ve r Mo dule Bo ard
WIDE
CAPACITY
16
18211 MB
16
18211 MB
16
1-3