4. Pull the Water Tray out and remove the
two Cold Evaporation Filters.
NOTE: Handle the Cold Evaporation Filters
by the edges to avoid touching it directly
and preventing possible contamination of
the filter element.
5. Remove the replacement Cold Evaporation
Filters from packaging and install in Water
Tray.
6. Replace Cold Evaporation Filters in Water
Tray.
7. Slide Water Tray back into place.
8. Press and lower Electrolysis Panel then
close and lock the side panel.
9. Refer to Preparation for Operation on
Page 9 and prepare the salt water
solution for the Sterilizer before resuming
operation.
10. Turn on the Sterilizer. After replacing
the filter, press and hold the Filter Reset
Button for 3 seconds to reset the filter life
countdown.
9
Only use genuine D&HLifelabs
CleVaFilter&AquaSoFilter with your
AquaSolvo Eco Ambient Air Sterilizer .
Use of any other filters may compromise
the proper operation of your unit and
potentially void your warranty .
•4-in-1 HEPA Filter: Part Number AS04FT-2
•Cold Evaporation Filter: Part Number
AS04FT-1
To purchase replacement filters or accessories
visit www.D&HLifelabs.com
Troubleshooting
Symptom
Probable Cause/Solution
Sterilizer does not operate.
Power cord not securely plugged into outlet. Make sure plug is
securely inserted.
No AC power. Check fuse or circuit breaker. Replace fuse with a
time delay type or reset the circuit breaker.
Sterilizer air flow is low.
Make sure air inlet is clear of obstructions. Check air inlet and
clean as necessary.
Air coming from Sterilizer has
Water tray is dirty or has contaminated water in it. Discard any
a bad odor.
water that is in the tray and thoroughly clean it, then refill with
clean fresh water and salt.
NOTE: The first time you use the Sterilizer, you might perceive
a plastic or paint smell. This is normal, but it should disappear
quickly. If the smell persists or if you sense a burning smell,
please disconnect the Sterilizer and contact Customer
Assistance.
Hypochlorous acid concentration is too high. Make sure the
room size setting is not too large. If the odor is still too strong,
you can disable the HOCl function using the HOCl Disinfection
button on the control panel
Windows or doors are open. Constant introduction of dirty
air from outside the room can reduce the effectiveness of the
Sterilizer. Close all exterior doors and windows.
Check Water Tray and the CEF and clean or replace as
necessary.
Water added to Sterilizer but
Check that Water Tray is properly seated in the Sterilzer.
Water Level indicator still
flashing displayed.
Salt Level indicator displayed
It takes some time to dissolve the salt and monitor the actual
even after salt has been
concentration. If necessary discard salt water solution and mix a
added.
new batch.
Salt Level indicator flashing
Make sure amount of salt added is correct. If necessary discard
after salt has been added.
salt water solution and mix a new batch.
Sterilizer has been tipped
Immediately unplug the power cord. Return Sterilizer to upright
over.
position. Open side panel and wipe dry any water you see.
Allow the Sterilizer to completely dry before restarting it.
10