Table 1-33. Threshold Settings and Converting Formulas
Sensor
Sensor Name
Number
52h
VCORE 2
Temperature
21h
MLB TEMP 1
22h
MLB TEMP 2
23h
MLB TEMP 3
61h
Processor 1 Temp Actual_Reading (degrees C) = Raw_Data
62h
Processor Temp 2 Actual_Reading (degrees C) = Raw_Data
2Ah
FCB Ambient1
2Bh
FCB Ambient2
The Converting Formula
Upper non-
Upper
recoverable
critical
Actual_Reading (Volts) = Raw_Data x 0.0116
0xFF
0xFF
Actual_Reading (degrees C) = Raw_Data
0x5A
0x57
Actual_Reading (degrees C) = Raw_Data
0x5A
0x57
Actual_Reading (degrees C) = Raw_Data
0x5A
0x57
0x5A
0x55
0x5A
0x55
Actual_Reading (degrees C) = Raw_Data
0xFF
0x32
Actual_Reading (degrees C) = Raw_Data
0xFF
0x32
Upper
Lower non-
non-critical
recoverable
0xFF
0x00
0x55
0x00
0x55
0x00
0x55
0x00
0x51
0x00
0x51
0x00
0x00
0x00
0x00
0x00
Using the Baseboard Management Controller
Lower
Lower
critical
non-critical
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
39