A quick and easy guide to setting up the Dell PowerEdge C8000
Refer to the C8000XD owner's manual for more zoning options used in different
hard drive configurations.
The C8220 and C8220X compute
sleds have an internal SAS RAID controller
to connect to internal drives. To connect
the C8000XD storage sleds to the
compute sleds, an external SAS controller
must be installed in the available PCI
Express slot. The external SAS controller
is a dual-port card with four external
connections. SAS cables must be
connected between these ports and the
C8000XD storage sled.
Figure 14 shows the C8220X
connected to two C8000XD storage sled
in a Single Port mode configuration. In
this configuration, one end of a SAS cable
is plugged into the top port of the
C8220X external controller and the other
end is connected to port A1 on the
C8000XD. This provides connection to the
first C8000XD sled. To connect the second C8000XD, plug one end of the SAS cable to
port B1 on the first storage sled and connect the other end to the second C8000XD in
port A1. This provides communication to both storage sleds and gives maximum storage
capacity for the C8220X compute sled.
Because the C8000 chassis can be configured in multiple ways, there are several
cabling possibilities. For example, in a configuration with a C8220X compute sled and
C8000XD storage sled in the same chassis, the SAS cable would stretch across the
chassis. For this situation and as a best practice in general, take the following two notes
into consideration.
NOTE: When cabling the compute sleds to the storage sleds, it is best practice to
have them positioned on top of each other in the server rack so they are lined up
vertically and cable between those units. Stretching cables across the chassis is messier
and can restrict airflow.
3
Figure 14: SAS cable installation.
A Principled Technologies setup guide 13