Figure 8. AC PSU status indicator
1
AC PSU status indicator/handle
Table 3. AC PSU status indicator codes
Power indicator codes
Green
Blinking amber
Not illuminated
Blinking green
Blinking green and turns off When hot-plugging a PSU, the PSU handle blinks green five times at a rate of 4 Hz and turns off. This

Locating serial number of your appliance

To get support for your appliance, use the VxRail Appliance serial number, also called the Product Serial Number Tag (PSNT). The PSNT is
a 14-digit number used to identify your appliance to Dell EMC support.
NOTE:
Only use the VxRail Appliance serial number to contact Customer Support. Sometimes, you may need to supply the 7-
digit Service Tag number.
There are two identification tags on your appliance:
The VxRail appliance serial number—You can find the serial number in VxRail Manager, or printed on the information tag.
The Service Tag — You can find the Service Tag printed on the physical appliance.
12
Overview
Condition
A valid power source is connected to the PSU and the PSU is operational.
Indicates a problem with the PSU.
Power is not connected to the PSU.
When the firmware of the PSU is being updated, the PSU handle blinks green.
CAUTION:
Do not disconnect the power cable or unplug the PSU when updating firmware. If
firmware update is interrupted, the PSUs do not function.
indicates a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage.
CAUTION:
The PSUs must have the same type of label; for example, Extended Power
Performance (EPP) label. Mixing PSUs from previous generations of VxRail servers is not
supported, even if the PSUs have the same power rating. This results in a PSU mismatch
condition or failure to turn the system on.
CAUTION:
When correcting a PSU mismatch, replace only the PSU with the blinking indicator.
Swapping the PSU to make a matched pair can result in an error condition and unexpected
system shutdown. To change from a high output configuration to a low output configuration or
vice versa, you must turn off the system.
CAUTION:
If two PSUs are used, they must be of the same type and have the same maximum
output power.