Allied Telesis Converteon AT-CV1KSS Fiche technique - Page 2

Parcourez en ligne ou téléchargez le pdf Fiche technique pour {nom_de_la_catégorie} Allied Telesis Converteon AT-CV1KSS. Allied Telesis Converteon AT-CV1KSS 2 pages. Converteon line card
Également pour Allied Telesis Converteon AT-CV1KSS : Fiche technique (3 pages), Manuel d'installation (2 pages)

Allied Telesis Converteon AT-CV1KSS Fiche technique
AT -CV1KSS
| Converteon Series Line Card
Link Test, MissingLink and Smart
MissingLink Functions
Link Test
The link test is a fast and easy way for you to test the
connections between the media converter ports and the
end-nodes that are connected to the ports. If a network
problem occurs, you can perform a link test to
determine which port is experiencing a problem, and so
be able to focus your troubleshooting efforts on the
cable or end-node where the problem resides.
MissingLink
The MissingLink feature enables the two ports on the
media converter to pass the 'Link' status of their
connections to each other. When the media converter
detects a loss of connection to an end-node, the media
converter shuts down the connection to the other port,
thus notifying the end-node that the connection has
been lost.
Smart MissingLink
The Smart MissingLink feature performs exactly the same
function as MissingLink with one additional feature.
When a link is lost on a port, the LINK LED of the
port which still has a valid connection to its end-node
starts to blink. This allows you to quickly determine
which port still has a valid connection
(LINK LED blinking) and which port has lost its
connection (LINK LED off).
Technical Specifications
Status Indicators
Status LEDs
System LEDs
LED
Color
Description
RDY
Green
The line card has passed
diagnostics
Off
The line card has not
passed diagnostics
ML
Green
MissingLink mode is
enabled
Off
MissingLink mode is
disabled
SML
Green
Smart MissingLink mode
is enabled
Off
Smart MissingLink mode
is disabled
SFP Port LEDs (per port)
LED
Color
Description
LK
Green
Link established on the port
Flashing
When Smart MissingLink
is enabled, if a link has
failed, this shows the port
that still is correctly
connected
USA Headquarters
|
19800 North Creek Parkway
European Headquarters
|
Via Motta 24
Asia-Pacific Headquarters
|
11 Tai Seng Link
www.alliedtelesis.com
© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
Off
AT
Green
Off

DIP Switches

The AT-CV1KSS line card features only the Diagnostic
Mode DIP switches.
The table below lists the positions of the DIP switches.
Operating Mode
Smart MissingLink (SML)
MissingLink (ML)
Link Test (default)
Manufacturing Default Settings OFF
'x' means the DIP switch position could be either ON or OFF.

Physical Specifications

Dimensions:
(W x D x H)
Weight:

Optical Characteristics

Dependent on the SFPs used. See datasheets for specific
SFPs.
Packet Size
Maximum packet size = Infininate - no frame buffer
Power Characteristics
Power consumption

Environmental Specifications

Maximum operating temperature: 0°C to 40°C
Maximum storage temperature:
Operating and storage altitude:
Relative humidity operating
and storage:
Predicted MTBF (Telcordia SR332): 1,370,000 hrs
|
Suite 200
|
Bothell
|
WA 98011
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
Singapore
|
534182
|
T: +65 6383 3832
No link established on the
port
TX/RX activity detected on
the port
No activity detected on
the port
DIP 1 DIP 2 DIP 3
OFF
ON
X
ON
OFF
X
OFF
OFF
X
OFF
OFF
2.2cm x 7.3cm x 13cm
(.855" x 2.89" x 5.1")
0.27 kg (0.60 lbs)
4.75W
(32°F to 104°F)
-25°C to 70°C
(-13°F to 158°F)
Up to 3,048 meters
(10,000 feet)
5% to 95%
(non-condensing)
|
USA
|
T: +1 800 424 4284
|
F: +41 91 69769.11
|
F: +65 6383 3830
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Immunity:
EN55024
Safety:
UL60950-1 (cULUS), EN60950-1 (TUV)

Ordering Information

AT-CV1KSS
Gigabit Ethernet Converteon media converter line card
1000X SFP to 1000X SFP
Associated Products
AT-SPSX
1000SX (SC), 220m multi-mode Fiber Gigabit module
AT-SPLX10
1000SX (SC), 10m single-mode Fiber Gigabit module
AT-SPTX
1000T, 100m copper Gigabit module
AT-CV1000-xx
Single slot Converteon chassis
AT-CV1203-xx
Two slot Converteon chassis
AT-CV5000-xx
18 slot, Converteon chassis
|
F: +1 425 481 3895
617-000142 RevE