DHA Four-channel DC Controller DMX Manuel d'instruction et d'entretien - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction et d'entretien pour {nom_de_la_catégorie} DHA Four-channel DC Controller DMX. DHA Four-channel DC Controller DMX 12 pages.
7
P o w e r O u t p u t P r o t e c t i o n
The motor drive outputs are protected by a self-resetting thermal cutout.
This provides protection against short circuits and also protects motors
from burnout due to stalling by external force or overloading.
When a short circuit or overload occurs on an output channel the output on
all channels will be greatly reduced and the main (red) power LED will be
dimmed significantly. After a few seconds the thermal cutout will be
activated on the short-circuit channel and the remaining channels will
return to normal operation. The cut-out time will vary depending on the
output settings of the controller but, provided that external wiring
conforms to the standard recommended by DHA Lighting, there will be no
immediate damage to either the DC controller or any DHA moving effects
connected.
While the fault persists the affected channel will remain in shutdown. The
controller should not be left in this state for any prolonged period.
The DC controller should recover in a matter of seconds once the source of
the fault is removed.
9