Dell PowerEdge Manuel de gestion du système - Page 17
Parcourez en ligne ou téléchargez le pdf Manuel de gestion du système pour {nom_de_la_catégorie} Dell PowerEdge. Dell PowerEdge 28 pages. Vmware esxi software on servers
Également pour Dell PowerEdge : Manuel du portefeuille (27 pages), Manuel rapide (6 pages), Manuel d'utilisation (44 pages), Manuel de l'utilisateur (20 pages)
Problem
Health status of
components in
MD1000/MD1120
is not available in
VI Client
RAID10 virtual
disks show up as
"RAID Level
Unknown" in VI
Client
PERC Battery
health status is
not properly
reported in VI
Client
VI Client does not
report Critical
Array Assert for
the removed drive
on PE1950
VI Client reports
Critical Array
Assert for all
physical drives in a
logical volume if
one physical drive
fails
Description
Health status of hardware
components like fans,
controller, and power supply of
MD1000/MD1120 is not
available in VI Client.
The RAID level 10 is shown as
"RAID Level Unknown" Logical
Volume in VI Client.
When battery health status
becomes critical, the battery
status sensor is removed from
the VI Client.
When a drive is removed from a
configured Logical Disk in SAS
6i/R, VI Client does not show
the Critical Array Assert for the
failed drive.
VI Client reports Critical Array
Assert for all physical drives in a
logical volume if one physical
drive fails.
Storage
Resolution
MD1000/MD1120 is not
supported with ESXi. Health
status of hardware components
of MD1000/MD1120 is not
implemented in ESXi.
This is a known issue with this
release of ESXi.
This is a known issue with this
release of ESXi.
This is a known issue with this
release of ESXi.
This is a known issue with this
release of ESXi.
Systems Management Guide
17