System Overview : Dell PowerVault 220S and 221S Systems Service Manual
Power supply and cooling module
Power Supplies
Wattage
Heat dissipation
Voltage
Frequency
Amperage
Physical
Height
Width
Depth
Weight
PowerVault 220S
PowerVault 221S
Environmental
Temperature:
Operating
Storage
Relative humidity
Operating
Storage
Altitude
Operating
BTU per hour
Available Hard-Drive Power (Per Slot)
Supported hard-drive power consumption
file:///C|/Users/rishi_sood/Desktop/220s/en/sm/intro.htm[3/7/2013 12:09:13 PM]
3 LED status indicators for power supply status, power supply fault, and AC status and 2 for cooling module fault
600 W
200 W
100–240 V rated (actual 85–264 V)
50–60 Hz
9.4 A at 100 V, 4.6 A at 200 V
13.26 cm (5.22 inches)
44.58 cm (17.55 inches)
50.8 cm (20 inches)
32.4 kg (71.5 lb) maximum redundant configuration with all hard drives installed
42.2 kg (93.0 lb) maximum redundant configuration with all hard drives installed
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
8% to 80% (noncondensing)
8% to 95% (noncondensing)
–16 to 3048 m (–50 to 10,000 ft)
2750
up to 1.3 A at +12V
up to 1.5 A at +5V