Dell Storage Center SC220 Manuel d'entretien - Page 27
Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Dell Storage Center SC220. Dell Storage Center SC220 36 pages. Storage enclosures
Également pour Dell Storage Center SC220 : Pour commencer (14 pages), Manuel du propriétaire (27 pages)
Setting
Data Bits
Stop Bits
Flow Control
e Turn off line wrapping.
f
Press Enter several times to initiate the connection. The terminal echoes back to
indicate that connectivity has been established. If the prompt > is not displayed,
verify that the communications settings are correct and the physical serial
connection is good.
g Enter the following command to switch to developer mode:
shellaccess developer
h Enter the following command and note the jbod index and enclosure values
displayed in the output:
jbod enclosure show
i
Enter the following command to reset the Service tag. Replace
enclosure
determined in
jbod enclosure setServiceTag
"
23 Perform a Phone Home and contact Dell Technical Support Services as described on
page
Replacing Rack Rails
Rack rails are used to install SC200 and SC220 enclosures into a rack.
Note: This procedure contains high-level steps. For detailed instructions, see
Rack Installation Instructions at
md1220/en/index.htm.
Use this procedure to replace rack rails.
1 Shut down the controller(s) and enclosure(s) as described on
2 Remove the enclosure from the rack rails.
3 Remove the rack rails from the rack.
4 Install the replacement rack rails in the rack.
5 Install the enclosure in the rack rails.
6 Start up the controller(s) and enclosure(s) as described on
Dell Compellent
Note: To facilitate troubleshooting, enable logging for the session.