Dell Force10 S25P Manuel - Page 29
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Dell Force10 S25P. Dell Force10 S25P 48 pages. Installing the s25p system
Également pour Dell Force10 S25P : Manuel de démarrage rapide (27 pages)
Chapter 4
This chapter contains these major sections:
•
Accessing the Console Port
•
Installing Optics on page 30
—
Installing SFPs on page 31
—
Installing XFPs on page 32
Accessing the Console Port
Connect the RJ-45/DB-9
adapter that is shipped with
the S25P system to the
RJ-45 cable.
Console port pinout:
Pin 1 = NC
Pin 2 = NC
Pin 3 = RXD
Pin 4 = GND
Pin 5 = GND
Pin 6 = TXD
Pin 7 = NC
Pin 8 = NC
To access the console port, use the following procedure.
Step
Task
Install the RJ-45 copper cable that is shipped with the S25P system into the console port.
1
You must install a straight-through RJ-45 copper cable (a standard Ethernet cable) into the
Caution:
console port. This is different from many other implementations that require an Ethernet crossover
cable (or rollover cable). If connecting to a terminal server and using a crossover cable, daisychain
another crossover cable to effectively get a straight-through cable connection. Many console terminal
servers use octopus cables that are crossover cables. To accommodate the octopus cable, connect an
additional crossover cable, as above, to effectively install a straight-through cable.
Installing the S25P System
Figure 18 Console Port of S25P
Installing Ports
Set your initial console terminal settings
to match the default console settings on
the switch:
•
•
•
•
•
After establishing a connection, you can
modify the settings to match at each end
of the connection.
9600 baud rate
No parity
8 data bits
1 stop bit
No flow control (console port
only)
29