Summary
Max number of OSPF neighbors not
supported
Cable fault distance not getting displayed
in WEB in case of cable with one or more
pairs cut or short.
Ports representation need to be changed
in debug messages
No error message for illegal characters in
various command parameters
The ARP entry is not seen in the ARP
table when an ARP reply is sent to DUT.
Mapping Table configuration is not being
displayed on Read-Only mode user web
page.
ACL is getting deleted when trying to
create max+1 rule.
LLDP-Med TLV information not
registered for jumbo frame sizes greater
than 8000
VLAN binding entries are not being
displayed on Read-Only mode user web
page.
Unable to execute the command dot1x
timeout tx-period 1
In switching> network security >dot1x
authentication web page in read-only user
mode, the Re-Authenticate Now check
box can be checked
System Device information web page
LED information not in sync with front
panel LED information.
DHCP snooping static binding thru
DHCP request is denied as this is a
expected behavior.
Mode of transfer is displaying
"unknown," while downloading the code
from ftp
Allow disabling and enabling of terminal
paging
Web does not allow to configure image
descriptor to its max length i.e. 255
characters.
18
User Impact
User confusion over switch
operations.
User confusion over switch
operations.
User confusion over switch
operations. Inability to diagnose
network issues.
User confusion over switch
configuration.
User confusion over switch
operations. Inability to diagnose
network issues.
User confusion over switch
configuration.
User confusion over switch
operations. Possible security
issues.
User confusion over switch
operations.
User confusion over switch
operations.
User confusion over switch
operations.
User confusion over switch
operations. Possible security issue.
No user impact expected.
User confusion over switch
operations.
User confusion over switch
operations.
User frustration over switch
configuration.
User confusion over switch
operations.
Workaround
The maximum number of neighbors is
supported.
The fault distance is displayed in the web
page.
Ports are now displayed in C/S/P standard
format
The accepted character set and length is
documented in the CLI reference manual.
ARP entries are stored properly
The mapping table is displayed for a read-
only user.
Corrected error checking logic.
Jumbo LLDP frames are now processed
properly
VLAN binding entries are available to
read only users
This command is accepted with a timeout
period of 1 second. Corrected range check
on input.
Read-only properties are set for the check
box
This issue was regarding various stylistic
aspects of the system device web page.
The system device web page conforms to
the requirements as it exists and does
necessarily match the CLI with regarding
to capitalization or naming conventions
Removed the log message indicating that a
bound DHCP client with an existing
binding sent a DISCOVER. Added a
counter for this condition to the DHCP
debug statistics.
ftp transfer mode is displayed
The terminal length command is now
implemented.
Images descriptors up to 255 characters
are allowed
System Firmware Version 4.1.0.6