Dell PowerEdge M520 Manuel de l'utilisateur - Page 23

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Dell PowerEdge M520. Dell PowerEdge M520 23 pages. Dell poweredge blade servers getting started guide
Également pour Dell PowerEdge M520 : Information Update (38 pages), Notes de mise à jour (27 pages), Manuel (25 pages), Informations importantes Manuel (35 pages), Manuel de mise à jour (32 pages), Manuel de mise à jour (28 pages), Manuel de l'utilisateur (26 pages), Manuel de l'utilisateur (22 pages), Manuel de démarrage (12 pages), Manuel technique (46 pages), Manuel technique (45 pages), Manuel du portefeuille (27 pages), Manuel de démarrage (14 pages), Manuel de démarrage (12 pages)

Dell PowerEdge M520 Manuel de l'utilisateur
Rev 1.0
Table 9 - SFP+ Pinout
Pin
Symbol Name
15
VccR
16
VccT
17
VeeT
18
TD+
19
TD-
20
VeeT
a. Circuit ground is internally isolated from chassis ground.
b. T
FAULT
Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V
to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias cur-
rent or the TX output power exceeding the preset alarm thresholds. A low output indicates
normal operation. In the low state, the output is pulled to <0.8V.
c. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V
d. Should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V.
MOD_ABS pulls line low to indicate module is plugged in.
e. LOS is open collector output. Should be pulled up with 4.7kΩ – 10kΩ on host board to a
voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of
signal.
24
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground (Common with Receiver Ground)
Transmitter Non-Inverted DATA in. AC Coupled.
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground (Common with Receiver Ground)
is an open collector/drain output, which should be pulled up with a 4.7k – 10k
Description
a
a