Dell S3100 Series Manuel de démarrage - Page 14
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage pour {nom_de_la_catégorie} Dell S3100 Series. Dell S3100 Series 27 pages.
Également pour Dell S3100 Series : Manuel de démarrage (46 pages), Manuel d'installation (45 pages)
WARNING: The PSU side includes two slots, PSU1 and PSU2. Although
the switch can run on one PSU, Dell Networking highly recommends
using two PSUs for full redundancy and additional cooling. To avoid
overheating when the switch is running with only a single PSU, Dell
Networking recommends using PSU1 (on the left when facing the PSU
side) and covering the second PSU slot opening (PSU2) with a blank
plate.
CAUTION: To prevent electrical shock, ensure that the system is
grounded properly. If you do not ground your equipment correctly,
excessive emissions may result. To ensure that the power cables meet
your local electrical requirements, use a qualified electrician.
CAUTION: Remove the power cable from the PSU prior to removing
the PSU itself. Do not connect power prior to inserting the PSU in the
switch.
NOTE: Ensure that the PSU is correctly installed. When you correctly
install the PSU, the power connector is on the right side of the PSU.
NOTE: Dell Networking recommends supplying power from the switch
PSU to the external power source only after the chassis is mounted in a
rack or cabinet.
Installing a Fan Tray
To install a fan tray, follow these steps:
NOTE: The fan tray is hot-swappable.
1.
Take the fan tray out of the shipping box.
2.
Use the grab handle on the fan tray to slide it into the bay.
3.
Tighten the captive screws on the fan tray with a screwdriver. Ensure that
the fan tray is secure.
14
Installation