Dell S6010-ON Manuel d'installation - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Dell S6010-ON. Dell S6010-ON 46 pages.
Également pour Dell S6010-ON : Notes de mise à jour du micrologiciel (12 pages)

Dell S6010-ON Manuel d'installation
LED
QSFP+ port when used as four ports of 10G. All four LEDs are used. •
Stack number
Management port Link LED
Management port Activity LED
Fan
Power
Figure 6. S6010–ON PSU-side LEDs
1
Fan LED
Table 2. S6010–ON PSU-side LED behavior
LED
Fan LED
10
S6010–ON System
Description
Blinking amber one second on/one second off—port locator
function
Off—No Link
Solid amber—4x10G speed
Blinking amber—port activity at 4x10G speed
Blinking amber one second on/one second off—port locator
function
Displays the stack unit number of the switch
Displays "1" if switch is not part of a stack
Off—no link
Solid green—link on 1G speed
Solid amber—link on 10/100 Mbps speeds
Off—no link
Blinking green—transmit/receive is active
Solid green—fan powered and running at the expected RPM
Blinking amber—fan failed, including incompatible airflow
direction when you insert the PSU or fan trays with differing
airflows
Solid green—normal
Solid amber—POST is in progress
Blinking amber—power supply failed
Off—no power
2
PSU LED
Description
Off—no power to fan/failure