Table 8. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 9. AC power requirements
Parameter
Power supply
PSU maximum power capability
Typical power consumption
Table 10. DC power requirements
Parameter
Minimum and maximum input voltage range
Input power at full load
Input current at full load
Start up VDC
Start off VDC
IEEE standards
The Z9100–ON complies with the following IEEE standards.
•
802.3ab Gigabit Ethernet (1000BASE-T)
•
802.3ae 10 Gigabit Ethernet (10GBASE-X)
•
802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
•
802.3ba 100 Gigabit Ethernet
•
802.3bj 100 Gigabit Ethernet
•
802.3bm 100 Gigabit Ethernet
Specifications
32° to 113°F (0° to 45°C)
NOTE:
Reduce maximum temperature by 1°C/300 meters
(1°F/547 feet) above 950 meters (3,117 feet).
5 percent to 85 percent (RH), non-condensing
–40° to 158°F (–40° to 70°C)
5 percent to 90 percent, non-condensing
292.42 BTU/hr 85.7 W
10,000 feet (3,048 meters)
39,370 feet (12,000 meters)
SV0115 — ODM
Specifications
100–240 VAC 50/60 Hz
606 Watts
288 Watts
Specifications
−48, –60V DC, 32A Max
−40.5 V/970 W −48 V/930 W −60 V/950 W (without fan)
−40.5 V/980 W −48 V/940 W −60 V/960 W (with fan)
−40.5V/23.8A −48V/19.0A −60V/15.6A (without fan)
−40.5V/24.0A −48V/19.2A −60V/16.0A (with fan)
39.0+/−1.5 V
37.5+/−1.5 V
Specifications