1.10.2 Temperature too high
\ | /
-
/ | \
If a temperature of 95°C is exceeded, the alarm diode blinks for 10 seconds.
The current temperature value blinks alternatingly with an exclamation mark (!) at
the relevant position for as long as the threshold value is exceeded.
1.10.3 Display / receiver battery weak
If the battery voltage reaches a critical value, the battery symbol blinks
continuously. Please replace the battery (type CR2450) as soon as possible.
1.10.4 Sensor battery status critical
If "Lo" appears at a tyre position on the display, please contact a tyre specialist
company or workshop to replace the sensor.
If the outside temperature is below 10°C, this message can be disregarded. Once
the temperature rises above 10° C, the system will work again in the accustomed
manner.
-
\ | /
-
-
/ | \