360 Vision Affiniti Thermal IP Manuel d'installation et de configuration - Page 18
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et de configuration pour {nom_de_la_catégorie} 360 Vision Affiniti Thermal IP. 360 Vision Affiniti Thermal IP 20 pages.
Affiniti Thermal IP Install Manual V2.1.17.3
Camera Maintenance
•
Firmware - Browse to codec file and then click on open. The camera codec will then be updated. The
Affiniti Thermal IP camera will re-boot once the update has been performed.
DO NOT interfere with this process as it may stop the camera from working.
Contact 360 Vision Technical Support for the link to the codec update files.
6 Network Settings Recovery
When network settings are changed, the IP address, Net Mask and Gateway are validated before they are
saved. However if the settings are such that the Affiniti Thermal IP has settings which mean that it cannot
be seen on the user's network, it may become necessary to use the 'Network Settings Recovery' feature as
described below.
The 'Network Settings Recovery' IP address may conflict with an IP address that is already defined on the
network, it may be necessary to disconnect the Affiniti Thermal IP from the network and control it locally using a
network connection to a laptop so that the IP address can be set to a suitable setting before the Affiniti Thermal
IP is reconnected to the main network.
Procedure for 'Network Settings Recovery'
Disconnect the Affiniti Thermal IP from the network, until process is complete.
Turn power to the Affiniti Thermal IP OFF for 3 seconds.
Turn power to the Affiniti Thermal IP ON for approx. 1 minute.
Repeat the above three times.
On the final power ON, leave the power switched on for at least 5 minutes to allow the Affiniti Thermal IP to
initialise.
(See section Locating the Affiniti Thermal IP on your network - page 7).
7 Special Presets
Thermal Camera
Seek 102
Seek 103
Seek 104
Seek 105
Seek 106
Seek 107
Seek 108
© 360 Vision Technology Ltd.
Digital Zoom Off
Digital Zoom x2
Digital Zoom x4
Display Blue Spot, Read Spot Temperature
Remove Spot Temperature
Turn Off all thermal alarms
Perform FFC
Page 18