Drain pump
Max. temperature
Drain hose (int. diameter)
On-site hose connector for drain hose
(int. diameter x length)
Max. transient throughput
Drain pump head height (from floor level)
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of suffi-
cient cross-section.
Dump valve
Max. temperature
Machine-side drain connection (ext. diameter)
On-site drain (int. diameter)
Max. transient throughput
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of suffi-
cient cross-section.
Fittings for base
Miele base UG/UO 6008
/ floor installa-
4 × metal angled brackets
tion
(to secure machine to base)
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Base must be bolted to the floor. Machine must be fixed to the
base.
Fixing materials for a floating screed floor are to be provided
on site.
Miele US 6008 base
4 × metal angled brackets
(to secure machine to base)
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Base must be bolted to the floor. Machine must be fixed to the
base.
Fixing materials for a floating screed floor are to be provided
on site.
Installation on floor or concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the base or floor. Fittings are
supplied with machine.
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
Unit depth
Unit height
Casing width
Casing depth
Minimum width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Minimum rear wall gap (to front of machine)
Recommended rear wall gap ensures sufficient space for
maintenance and servicing.
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and
program selected)
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
Installation should only be carried out by authorized installers in accordance with valid regulations! Observe installation
instructions when installing machine! All rights reserved!
Technical datasheet: PW 6080 LP/AV
Date: 2015-Sep-02
203 °F
95 °C
7/8''
22 [DN 22] mm
22 x 30 mm
7/8'' x 1 3/16''
6.9 gal/min
26 l/min
39 3/8"
1000 mm
203 °F
95 °C
2 15/16''
75 [DN 70] mm
2 15/16''
75 [DN 70] mm
16.4 gal/min
62 l/min
5/16'' x 2 9/16'' 8 x 65 mm
1/2'' x 2 3/8"
12 x 60 mm
1/4'' x 2"
6 mm x 50 mm
8 mm x 40 mm
5/16'' x 1 9/16''
1/4'' x 2''
6 mm x 50 mm
8 mm x 40 mm
5/16'' x 1 9/16''
27 9/16''
700 mm
28 5/8''
727 mm
40 3/16''
1020 mm
27 1/4''
692 mm
27 3/16''
690 mm
28 3/8''
720 mm
43 5/16''
1100 mm
900 mm
35 7/16''
309 lbs
140 kg
2600 N
2600 N
1850 N
1850 N
750 N
750 N
22 Hz
22 Hz
2830 BTU/hr
0.83 kWh
<70 dB (A)
<70 dB (A)