Air extraction
Reducing Collar
(optional accessory)
If you would like to reduce the
environmental impact of your ventilation
system by limiting the CFM output the
Reducing Collar can be installed.
It reduces the air flow to less than
400 CFM.
Check local building codes for
max. CFM requirements.
^ Push the Reducing Collar on the
exhaust port of the fan.
^ Push the exhaust hose over it.
^ Fix both with a hose clamp.
34
Condensate trap
(optional accessory)
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and 6"
(150 mm) in diameter.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.