4.7 Resynchronization
This operation must be done only in case if it is repeatedly observed that the door doesn't reach the correspondant position of reclosing (or if it
tends to exceed it), or in case you find yourself in the conditions described at point 4.8.
The operation of resynchronisation consists on the activation towards the UP (completely closed) position at reduced velocity, with the
intent to find the point of total closure; the moving arrests automatically on the point in which you find a mechanical stop that hampers the move-
ment. This point is identified like position of closure (chain completely up).
Warning: During the operation of resynchronization, the intervention of the anti-squeezing security is interpreted like identification of the
closing position. To avoid the non-volontary intervention the sense results remarkably reduced respect to the conditions of its normal
functioning.
5. Advanced functions.
This procedure must be carried out ONLY by an installer and ONLY during setting up of the system. For correct setting, before carrying out altera-
tions, bring the chain to the completely closed position (up) (see paragraph 4.2).
5.1 Reset.
In case if it is necessary to reset the control unit proceed as follows: (total erasing of the memory and deactivation of pre-blinking, photocell test and
multi-user function )
1. Remove power supply from the system.
2. Set the selector SW1 on AUT (automatic).
3. Press the red button.
4. Keep it pressed while reconnecting the power supply
5. Keep it pressed until the flashing signal lights up for the 3rd time.
6. Release the button and wait until the flashing light turns off. The reset is done
5.2 Deleting of a single transmitter ( only with rolling code decoding).
In case if it is necessary to cancel a single transmitter, proceed as follows:
1. Set the selector SW1 on AUT (automatic).
2. Push the hidden button of a transmitter already learned, or push the red button of the control unit; the flashing light turns on.
3. Push the hidden button and at the same time the first button of the transmitter that you want to cancel, the flashing turns off and the deletion is
complete.
5.3 Selection of the type of decoding and tolal deleting of memory.
In case if it is necessary to change the decoding mode (from fixed mode to rolling code mode or vice versa) or to erase all the transmitters learned,
proceed as follows:
1. Remove power supply from the system.
2. Set the selector SW1 on MAN (manual).
3. Press the blue + red button at the same time if you want fixed code decoding or press only the red one if you want the rolling code decoding.
4. Keep them pressed while the power supply is reconnected to the system.
5. Keep them pressed until the flashing signal lights up for the 3rd time.
6. Release the buttons. At the end of the programming the flashing signal turns off. Set the selector SW1 on AUTO. The selection of the type of
decoding and the total erasing of the memory are done.
Note: This procedure executes a total deletion of the memory of the control unit. So you have the complete deletion of the parameters
previously memorized ( course of the gate, memorized transmitters) and the disconnection of the pre-flashing function. Therefore we
recommend to set the codification mode as first point, before any other programming.
To re-programm the total run of the chain it is not necessary to reset the memory!!!!
6-1622349 rev.3 28/03/2019
Press the first button of the trans-
mitter for more than 6 seconds and
release
The chain arrests temporarily (if in
movement) then starts again in closu-
re (upwards) at reduced velocity.
Yes
The chain arrests at the presence of
a mechanical stop memorizing the
position as completely closed