Miele DG 155-2 Manuel d'instructions d'installation - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Miele DG 155-2. Miele DG 155-2 12 pages. Steam oven
Également pour Miele DG 155-2 : Dimensions du produit (1 pages), Manuel d'instructions d'installation (12 pages)
Electrical connection
,
WARNING:
Disconnect main power supply
before servicing. To reduce the risk
of electrical shock, make sure that
the appliance is properly grounded
after installation.
All electrical work should be performed
by a licensed electrician, in strict
accordance with national and local
safety regulations and standards.
– Note to installer:
Please leave these instructions with
the consumer.
– Power supply:
Please check the data plate:
240 VAC; 60 Hz
15A, 240 V
L1, L2, Ground
Make sure your electrical supply
matches the data plate.
WARNING : THIS APPLIANCE
MUST BE GROUNDED
Installing the oven
For USA only
The appliance is provided with 3
terminal leads: 1 black wire (L1), 1 red
wire (L 2) and 1 green wire (GND) that
must be connected to a dedicated
junction box. Connect the black wire to
L1, the red wire to L2 and the green
wire to GND.
ALSO SEE THE WIRING DIAGRAM
PROVIDED WITH THE APPLIANCE.
For CDN only
The appliance is provided with 3
terminal leads: 1 black wire (L1), 1 red
wire (L 2) and 1 green wire (GND) that
must be connected to a dedicated
junction box. Connect the black wire to
L1, the red wire to L2 and the green
wire to GND.
All hot wires (black and red) must be
fused individually before connecting
them to the main power supply leads.
Use 15 Amp fuses or circuit
breakers for appliances rated 240
VAC.
ALSO SEE THE WIRING DIAGRAM
PROVIDED WITH THE APPLIANCE.
9