Miele DA 199-2 Manuel d'utilisation et d'installation - Page 27
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'installation pour {nom_de_la_catégorie} Miele DA 199-2. Miele DA 199-2 32 pages. Cooker
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the prob-
lem of condensation will need to be ad-
dressed.The exhaust ducting will need
to be suitably insulated.
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to col-
lect and evaporate any condensate
which may occur.
Condensate traps are available from
builders merchants.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the ex-
haust connection.
27