Retaining plate C should only be used if
dimension Y is greater than 14
(365 mm.) It provides additional
stability for the chimney extension.
^ At a maximum distance of 14
(365 mm) from the ceiling hold
retaining plate C against the wall and
use the notches to align it with the
center line. Mark the two drill holes.
^ Drill two
1
/
" (3 mm) holes into the
8
wall.
^ Secure retaining plate C with two
5 x 40 mm screws.
34
^ Hang the canopy on the angled
brackets on retaining plate A.
3/
"
8
3
/
"
8
^ Secure the canopy with 5 x 40 mm
screws into each drilled hole.