Également pour Miele DA 2360 : Instructions d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (36 pages), Instructions d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (36 pages), Instructions d'utilisation et d'installation (36 pages)

Miele DA 2360 Instructions d'utilisation et d'installation
Installation
a The ducting can also be connected at the back.
b 222 x 89 mm flat exhaust ducting can be used as an alternative for ducting to
the rear or to the side.
c The rangehood is secured in the cut-out by clamps. This requires that the
installation surface is made of a solid material, such as wood. Make sure that the
material is strong enough to bear the weight of the rangehood and the edge
extraction panel(s). There must be a minimum distance of 25 mm between the areas
around the clamps and any structures or components, such as struts or cables.
d Alternatively, the rangehood can be secured to four fixing points on an interim shelf.
e Additional fixing points on the installation surface.

Safety distance (S)

The minimum distances between the highest part of a cooktop (including
trivets, dials - depending on model) and the bottom of the rangehood are as
follows, unless a greater distance is specified by the manufacturer of your
cooking appliance. See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h total
output, with no burner having a greater output than
16.2 MJ/h.
Multi-burner gas cooktop with total output greater than
45.4 MJ/h, but with a maximum of 77.8 MJ/h, with no
burner having a greater output than 17.3 MJ/h.
Multi-burner gas cooktop with total output greater than
77.8 MJ/h, with a single burner having a greater output
than 17.3 MJ/h.
Single burner gas cooktop with a maximum output of
21.6 MJ/h.
Single burner gas cooktop with an output greater than
21.6 MJ/h, but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater than
29.2 MJ/h.
30
Minimum distance S
600 mm (AU, NZ)
450 mm (HK, MY, SG)
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible