Filter operating hours counter
The number of hours the appliance has
been in operation is stored in memory.
The indicator lamp for the grease filter
control will light up after 30 hours of op-
eration. The vapour plate and the
grease filter must then be cleaned.
After the vapour plate and the grease
filter have been cleaned and put in
place, the filter operating hours counter
must be re-set.
^ To do this, press the grease filter
touch control and hold for about
3 seconds.
The indicator lamp for the control will
go out.
Reading the filter operating hours
counter
To check the percentage of time set al-
ready used:
^ Press the On/Off touch control to
switch the fan on.
^ Press the grease filter touch control.
One or several of the indicator lamps
for the – /+ touch controls will flash.
The number of flashing lamps shows
the percentage of the operating time
which has already been used up.
1 lamp
= 25 %
2 lamps = 50 %
3 lamps = 75 %
4 lamps = 100 %
The number of operating hours used re-
mains in the memory, even when the
appliance is switched off or there is a
power cut.