Miele DA 3060 Instructions d'utilisation et d'installation - Page 29
Parcourez en ligne ou téléchargez le pdf Instructions d'utilisation et d'installation pour {nom_de_la_catégorie} Miele DA 3060. Miele DA 3060 36 pages. Cooker
Également pour Miele DA 3060 : Manuel d'utilisation et d'installation (36 pages)
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the
problem of condensation will need to
be addressed. The exhaust ducting will
need to be suitably insulated.
(optional extra)
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur. Condensate traps are
available for C 125 mm or C 150 mm
ducting.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust connection. The arrow on the
housing indicates the direction of
air-flow.
To achieve even further reductions in
noise levels, a special silencer can be
fitted in the ducting system.
On extraction models, it can be fitted
nearest the ducting outlet to the outside
to reduce neighbourhood noise, and on
recirculation models it can be fitted in
between the fan and the canopy.
29