Miele DA 3460 Manuel d'utilisation et d'installation - Page 29
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'installation pour {nom_de_la_catégorie} Miele DA 3460. Miele DA 3460 40 pages. Ventilation system
Également pour Miele DA 3460 : Manuel d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (40 pages), Manuel d'instructions d'installation (24 pages)
^ Remove the protective film between
the deflector plate and the casing.
^ Secure the front of the appliance to
the floor of the housing unit from
below using 4 screws (6 screws for
90 cm wide cooker hood).
To avoid damaging the deflector plate
when it is pulled out, care should be
taken to screw the fixing screws in
straight, and to ensure that the
screwheads are countersunk.
^ Secure the spacer strip to the back of
the appliance from behind using
4 plastic rivets as shown.
Attaching the lightshield
^ Attach the lightshield (if using).
A DML 400 installation kit, available as
an optional accessory, is required for
this (available as a special accessory).
Follow the installation instructions
supplied.
Weight of a lightshield matching
existing furniture
The lightshield must not exceed 1300 g
in weight.
This applies to lightshields with a depth
of up to 30 mm.
For larger or heavier lightshields, the
weight must be reduced by e.g.
machining it away at the back.
Installation
29