Miele DA 390-6 EXT Manuel d'utilisation - Page 27

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Miele DA 390-6 EXT. Miele DA 390-6 EXT 48 pages.

Protective foil

The housing components have
protective foil around them to prevent
them from transport damage.
 Please remove this foil before fitting
the housing components. It can be
peeled off easily.
 Draw two intersecting lines on the
ceiling.
 With air extraction mode:
– Place a section of the exhaust
ducting in the ceiling and feed it
down through the cross-sectional
area as illustrated. Exhaust ducting of
approx. 700 mm length is required
between the ceiling and the
rangehood exhaust socket.
– Secure the exhaust ducting to the
exhaust socket, e.g. with a hose clip
(available as an optional accessory)
on flexible ducting.
 Place the mains cable and for ...EXT
models, the connection cable to the
external motor, in the ceiling and
guide them through the ceiling in the
area shown. A mains cable of approx.
700 mm in length is required between
the ceiling and the rangehood
connectors.
Installation