de Mounting area (only d is required for recirculation hoods). Wall and ceiling
area for exhaust duct opening and for wall socket installation. Only the wall
socket installation is required for recirculation hoods.
Vent collar 6" (150 mm), with adapter 5" (125 mm).
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the "IMPORTANT SAFETY
INSTRUCTIONS" section.
Cooking appliance
Electric/Induction cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop
≤ 43,000 BTU/hr (12.6 W),
no burner > 15,000 BTU/hr (4.5 kW).
Multi-burner gas cooktop
≤ 73,800 BTU/hr (21.6 W),
no burner > 16,500 BTU/hr (4.8 kW)
Multi-burner gas cooktop
> 73,800 BTU/hr (21.6 W),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Single-burner gas cooktop
≤ 20,500 BTU/hr (6 kW)
Single-burner gas cooktop
> 20,500 BTU/hr (6 kW)
≤ 27,600 BTU/hr (8.1 kW)
Single-burner gas cooktop
> 27,600 BTU/hr (8.1 kW)
Installation
Minimum distance S
Miele
appliance
24" (610 mm)
26" (660 mm)
26" (660 mm)
30" (760 mm)
Not possible
26" (660 mm)
30" (760 mm)
Not possible
Non-Miele
appliance
30" (760 mm)
30" (760 mm)
27