Allmatic INVERTER COMPACT Instruction - Page 17

Parcourez en ligne ou téléchargez le pdf Instruction pour {nom_de_la_catégorie} Allmatic INVERTER COMPACT. Allmatic INVERTER COMPACT 20 pages.

Reset of the unit according to the display indications; this reset the control board to its factory settings
WARNING: all programming and personal settings must be repeated after the reset of the control board!
8.19 Backlighting of the display (Menù C - Display Light)
Enter MENU C and follow the instructions shown on the display in order to enable/disable the backlighting of the display itself.
The control board operates the function Energy saving which automatically switches off the display after the unit is inactive since some minutes. The
backlighting is automatically reactivated (if this function is enabled) when the user operates on the control board.
9. Electronic lock output
The functioning of the output is subordinated to the value assigned to the parameter "Motor brake": Parameter "Motor brake" OFF-1: On the output
a dry contact (without voltage) is available for the activation of the electric lock. The electric lock output can be activated after enabling the water
hammer during opening. Parameter "Engine brake": A clean contact (without voltage) is available at the output for the activation of an external electric
brake.
10. Tips for a successful installation
10.1 High speed movements
Problem
1) The motor stops for the effort during the movements.
2) It is easy to stop the automation during the movements
counteracting the movement.
3) The gate moves slowly despite having set an high speed
The motor stops and the control unit shows FAULT on the
display or 10 seconds of fast blinking.
10.2 Low speed movements (slowing down)
- The motor stops for the effort during the movements.
- It is easy to stop the automation during the movements
counteracting the movement.
- The gate moves slowly despite having set an high speed.
The correct setting of parameter is when you are not able to stop the automation when trying counteracting the movement.
The use of safety devices is absolutely necessary to ensure the safety of the automation.
11. Warning and advices
Avoid putting the connection cables of buttons, security devices and inputs close to those of the power supply of the control unit and of the motor.
Some parts of the control unit are subject to dangerous voltage. The control unit must be installed and programmed only by qualified professionals.
Always use a device that ensures the disconnection of all poles of the control unit's power supply.
This device can be a switch (connected directly to the power supply terminals) with a contact's minimum distance of 3 mm for each pole, or it can be a
device connected to the power network.
For connecting the card and the motors we recommend to use cables with double isolation as in compliance to the laws in force; the minimum cross
section of the single conductor must not be less than 1,5 mm² and not more than 2.5mm².
WARRANTY - In compliance with legislation, the manufacturer's warranty is valid from the date stamped on the product and is restricted to the repair
or free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The warranty
does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect product,
assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused by
environmental interference. The manufacturer's responsibility for damage caused to persons resulting from accidents of any nature caused by our
defective products, are only those responsibilities that come under Italian law.
Solution
Raise the torque supplied to the motor until problem is solved.
High Torque OP, High Torque OP.
Lower the speed of the motor until problem is solved.
High Speed OP, High Speed CL.
Lower the torque supplied to the motor until problem is solved.
High Torque OP, High Torque OP.
Lower the speed of the motor until problem is solved.
High Speed OP, High Speed CL.
- Raise the torque supplied to the motor until problem is solved.
Low Torque OP, Low Torque CL.
- Lower the speed of the motor until problem is solved.
Low Speed OP, Low Speed CL.
17 / 20