Miele PUR 68 W Instructions d'utilisation et d'installation - Page 30

Parcourez en ligne ou téléchargez le pdf Instructions d'utilisation et d'installation pour {nom_de_la_catégorie} Miele PUR 68 W. Miele PUR 68 W 40 pages. Ventilation system
Également pour Miele PUR 68 W : Instructions d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (40 pages), Instructions d'utilisation et d'installation (36 pages)

Miele PUR 68 W Instructions d'utilisation et d'installation
Installation

Installation recommendations

- When deciding on the safety distance
between the cooktop and rangehood,
please note that a distance of
650 mm above electric cooktops may
be preferable to give more working
space under the rangehood.
- Account should also be taken of the
height of the person who will be
using the rangehood most often.
They should have sufficient space to
work comfortably at the cooktop, and
be able to reach the rangehood
controls with ease.
- If positioned too high, extraction will
be inefficient.
- To achieve optimum vapour
extraction, the rangehood must be
positioned centrally over the cooktop,
not to the side.
- The cooktop should be no wider than
the rangehood and, if possible, it
should be narrower, especially for
safety distances greater than
750 mm.
- The installation area must be easily
accessible. The rangehood should be
easily accessible and easy to
dismantle in the event that service is
required. This should be taken into
consideration when planning the
position of cupboards, shelves,
ceilings or features in the vicinity of
the rangehood.
30
Drilling diagram for wall
mounting
 Please follow the directions given in
the installation instructions supplied
for drilling.
 For pre-installation of a back wall
where the holes have to be pre-
drilled, please refer to the drilling
distances in the drawing above
(screws  5 mm).
*The dimension for the middle wall
bracket is variable. It will depend on the
position of the wall vent and the socket.
It should be set as low as possible.