HP 124708-001 - ProLiant Cluster - 1850 Manuel de dépannage - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel de dépannage pour {nom_de_la_catégorie} HP 124708-001 - ProLiant Cluster - 1850. HP 124708-001 - ProLiant Cluster - 1850 18 pages. Proliant essentials foundation pack installation guide
Également pour HP 124708-001 - ProLiant Cluster - 1850 : Manuel de mise en œuvre (35 pages), Manuel de prévention des erreurs (12 pages), Livre blanc technique (12 pages), Mise à jour du micrologiciel (9 pages), Vue d'ensemble (20 pages), Manuel de mise en œuvre (26 pages), Manuel d'introduction (22 pages), Manuel de mise en œuvre (11 pages), Manuel d'installation (2 pages)

HP 124708-001 - ProLiant Cluster - 1850 Manuel de dépannage
Linux Operating Systems: Using /var/log/messages File
The Linux system log (/var/log/messages) can be viewed using the cat, more and less commands. The
following types of messages may be logged here if a memory problem has occurred:
Oct 11 01:51:18 dhcp57-150 hpasmd[12039]: WARNING: hpasmd: Corrected Memory Error threshold
exceeded (Slot 3, Memory Module 6)
[root@dhcp57-150 ~]# hplog -v
ID Severity
Initial Time
-------------------------------------------------------------
0011 Information
22:50 09/16/2004 22:50 09/16/2004 0001
LOG: IML Cleared (Administrator)
0012 Repaired
00:32 09/21/2004 00:32 09/21/2004 0001
LOG: Memory Cartridge Not Redundant (Slot 5)
0033 Caution
04:02 10/06/2006 04:02 10/06/2006 0001
LOG: Corrected Memory Error threshold exceeded (Slot 3, Memory Module 6)
DIMM Slot LEDs as Memory Problem Indicators
DIMM slot LEDs can be helpful indicators of issues with system memory. Figure 5 below gives an example of
the location of LEDs that will illuminate when certain DIMM slots indicate a failure. The example below is from
a ProLiant DL380 G4 system board; however, similar graphics for specific systems can be found in server
user guides and other system documentation.
Memory Problem Indicators
Example DL 380 G4
DIMM Slot LEDs on the System Board
9/5/2006
Figure 5: DiMM Slot LEDs
Update Time
Count
5
6
7
8
9
1
Amber = Memory
DIMM failure
failed
slot 6C
Off = Normal
Amber = Memory
DIMM failure
failed
slot 5C
Off = Normal
Amber = Memory
DIMM failure
failed
slot 4B
Off = Normal
Amber = Memory
DIMM failure
failed
slot 3B
Off = Normal
Amber = Memory
DIMM failure
failed
slot 2A
Off = Normal
Amber = Memory
DIMM failure
0
failed
slot 1A
Off = Normal
12
8