Installation

Installation, repair and maintenance work
should be by a Miele authorized service techni-
cian. Work by unqualified persons could be
dangerous and may void the warranty.
Pay careful attention to the enclosed installa-
tion instructions and the installation diagram.
Do not install the dryer in a room where there
is danger of frost.
Ensure that there is adequate ventilation for
operation in the room where it is installed.
Ensure that the air being drawn into the ma-
chine is fresh and that it does not contain chlo-
rine, fluoride or solvent fumes.
Machines heated by electricity must not be in-
stalled in the same room as dry cleaning
machines using solvents containing CFCs.
Escaping fumes will break down into hydro-
chloric acid if ignited. This will damage the
machine.
If installed in an adjacent room there must be
no exchange of air between them.
The central air inlet and the area around the
dryer must be kept free from lint particles, to
prevent machine damage.
The exhaust must not be led into a chimney
used by another gas, coal or oil heated appli-
ance. The warm humid air should be directed
by the shortest route into the open air or into a
suitable venting duct. The duct must be so de-
signed and installed to accommodate the high
throughput of air (few bends, as short a duct
as possible, well shaped and leakproof joints).
No filters or louvres should be built into the ex-
haust duct.
The connection between the exhaust ducting
and the exhaust connection on the dryer must
be airtight.
Where the exhaust is ducted directly into the
open air, the end of the duct should be pro-
tected against the weather, ideally by a down-
o
ward angle of 90
.
To facilitate cleaning of the duct, cleaning
flaps or covers should be fitted on the bends
wherever possible.
With upward sloping exhaust ducting a con-
densate drain must be made at the lowest
point.
The dryer is fitted with an exhaust fan which
can be heard during operation. The noise
level of the fan can be reduced by fitting a
muffler to the dryer vent stub (available from
Miele's Technical Service Department).
The minimum dimensions and distance re-
quired from the wall, as shown in the installa-
tion diagram, must be observed to allow
service to be performed.