E2
Overheating of the induction coils
ER03 &
Permanent use of keys;
Control unit cuts off after 10 sec
permanent tone
E5
Error on filter board
E6
Error on power unit
E7
cannot be cleary identified
E9
ER12
Control switches off after 10 sec
Control switches off after
ER13
60sec at the latest
ER16
Control switches off
ER20
Control unit cuts off after controlling
due to overheating to
ER21
avoid damage to the electronics
Key evaluation defective;
control unit cuts off
ER22
after 3.5
Secondary voltage of the power
supply unit too high (primary>300V).
ER25
Control switches off after 1s and a
permanent acoustic signal is heard
Relay voltage too high in switched
ER26
-off condition (nominal: 0 Volt)
ER31
Configuration data incorrect
ER33
NTC value is not within it s
specification (value < 200mV or
ER36
>4.9V; control unit cuts off)
Faulty feedback of shift register
signals to the segment
ER37
or relay activation
ER39
Secondary operational voltage is
ER40
min.5 s too low according to
identified Unterspannung
ER42
(1,8V< U
Communication error between
ER47
TC and induction
Secondary voltage of the power
unit to high (primary > 300V).
U400
Control unit cuts off after 1sec
releasing a permanent tone.
H Flashes
Controller flash defect; check sum not correct
Unknow error,
Coil temperature sensor defective
Short-circuit in the 5V or earthed control relay
Flash-failure
7.5 sec
Water on the glass above the control card
Wrong programming options (fuses, lockbits)
< 2,9V)
Powerfail
Hot pan on the control card; faulty radiant hotplate seal
/
Water or cooking utensils on the
glass above the control unit
5V short circuit with power unit
12V on power unit too low
temperature sensor at cooling body defect
mains synchronous impulse incorrect
Sub LIN error between filter and power unit
Component part defect
Short-circuit or disconnected
pan sensor or power supply
µC- faulty
Standard algorithm reaches limit when
overheated. Ambient temperature of
electronics still to high
Short-circuit or discontinuation at NTC
in the range of the key evaluation
Control wrong connected
Short circuit in the relay voltage control
Configuration data incorrect
Short-circuit or discontinuation at NTC
Return of sliding register signals to select,
segment or relay triggering incorrect
Primary PTC too hot
5V a the controller outside the valid range
or too much variance
None or faulty
communication
Control unit is wrongly connected.
Cooling down necessary
Cleaning of the
operational surface
Exchange filter board
Exchange power unit
turn-off and call Customer Service
Exchange temperature sensor
Exchange control unit
Exchange control unit
Remove the cause
(customer service)
Exchange control unit
Allow cavity to cool down.
Check heat sealing-off
of control unit.
Exchange control unit
Connect to correct mains voltage
Replace the control
Configuration necessary
Clean
Exchange control unit
turn-off and call Customer Service
turn-off and call Customer Service
Disconnect control unit from
the power system
turn-off and call Customer Service
Ensure that connection cable
is plugged on correctly
Connect to correct
mains voltage
Wait until the control card returns
to the normal temperature