Burkert 2033 Manuel de démarrage rapide - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Burkert 2033. Burkert 2033 19 pages. Piston-operated diaphragm valves

Burkert 2033 Manuel de démarrage rapide
3

INTENDED USE

Non-authorized use of the devices may be dangerous to
people, nearby
equipment and the environment.
▶ The diaphragm valves of Types 2030, 2031, 2031 K, 2032,
2033 and 2037 are designed for the control of contaminated,
ultra-pure or sterile media, as well as for abrasive or aggres-
sive media (also with higher viscosity).
▶ The device is designed for the controlled flow of liquid and
gaseous media.
▶ In the potentially explosion-risk area the diaphragm valves of
Types 2030, 2031, 2031 K, 2032, 2033 and 2037 may be used
only according to the specification on the separate Ex type
label. For use observe the additional information enclosed with
the device together with safety instructions for the explosion-
risk area.
▶ During use observe the authorized data, the operating condi-
tions and conditions of use specified in the contract docu-
ments and operating instructions.
▶ Protect device from damaging environmental influences
(e.g. radiation, humidity, steam, etc.). If anything is unclear,
consult the relevant sales office.
▶ The device may be used only in conjunction with third-party
devices and components recommended and authorized by
Bürkert.
▶ Correct transportation, correct storage and installation and
careful use and maintenance are essential for reliable and
faultless operation.
▶ The exhaust air may be contaminated with lubricants in the
actuator.
▶ Use the device only as intended.
4
english
Type 2030, 2031, 2031 K, 2032,
Intended use
4

BASIC SAFETY INSTRUCTIONS

These safety instructions do not make allowance for any
• contingencies and events which may arise during the instal-
lation, operation and maintenance of the devices.
• local safety regulations – the operator is responsible for
observing these regulations, also with reference to the instal-
lation personnel.
Risk of injury from high pressure and discharge of medium.
▶ Before working on the device or system, switch off the pres-
sure. Vent or drain lines.
Danger of bursting from overpressure.
▶ Observe the specifications on the type label for maximal
control and medium pressure.
▶ Observe permitted medium temperature.
Risk of injury from electric shock (when electrical component
installed).
▶ Before reaching into the device or the equipment, switch off
the power supply and secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regula-
tions for electrical equipment!
Risk of injury from moving parts in the device!
▶ Do not reach into openings.
2033, 2037