Miller 028042103 Manuel du propriétaire - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Miller 028042103. Miller 028042103 20 pages.
Également pour Miller 028042103 : Manuel du propriétaire (20 pages), Manuel du propriétaire (20 pages), Manuel du propriétaire (20 pages)

Miller 028042103 Manuel du propriétaire

3-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.

3-2. Specifications*

Coolant Tank
Capacity
Model
Hydracool 1
8 L
8 L
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40°C Above Ambient Temperature At A 1l/ Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 600 Amperes.

3-3. Coolant Specifications

Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -38
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).

3-4. Environmental Specifications

A. IP Rating
This equipment is designed for indoor use and is not intended to be used or stored outside.
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
C. Temperature Specifications
Operating Temperature Range
−10 to 40°C (14 to 104 °F)
.
The correction factor on the cooling power at an ambient temperature of 405C (1045F) is 0.625.
SECTION 3 − SPECIFICATIONS
Maximum Cooling
Capacity
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 0
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 0
Aluminum Protecting Coolant 043809*
°
°
C (-37
F) and resist algae growth.
Hydracool 1 IP21
Input Power
Cord with
Plug
Input Power
Single Phase
2 m
115 VAC
50/60 Hz
2.5 Amperes
Single Phase
2 m**
230 VAC
50/60 Hz
1.3 Amperes
IP Rating
Storage/Transportation Temperature Range
20 to 25°C (68 to 77 °F)
Dimensions
Length: 305 mm
Height: 674 mm
Width: 263 mm
Length: 305 mm
Height: 674 mm
Width: 263 mm
Coolant
°
°
C (32
F)
°
°
C (32
F)
ce-emc 4 2014-07
OM-254203 Page 5
Weight
20.7 kg
20.7 kg
IP21 2014−06
Temp1_2016- 08