Miller 300617003 Manuel du propriétaire - Page 22
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Miller 300617003. Miller 300617003 40 pages. Wire feeder
5-6. Setting Internal DIP Switches
Automatic Run-In (ON)
(Factory Default)
S1-1 And S1-2
On = Run-In speed is
approximately 1/2 weld wire
feed speed.
OM-1500-10 Page 18
P1
.
In the DIP switch S1 illustrations,
the elevated slider on each switch
is shown in white. For example,
the switches above are all in the
Off position.
.
When DIP switch positions are changed, the unit must be
turned Off and then On again in order for the new settings
to be active. DIP switches are only read on power up.
Position Settings And Results For DIP Switch S1 On PC1
Automatic Run-In (OFF)
S1-1 And S1-2
Off = Run-In speed is set using
potentiometer P1 located on Motor
Board PC1.
This illustration shows
the factory setting of S1.
1
Current Detect Override (ON)
S1-1 And S1-2
On = Current detect over-
ride. For welding power
sources that don't provide
current feedback through
the 14-pin receptacle. Run-
in is inactive.
Remove wrapper.
1
DIP Switch S1 On Motor
Board PC1
w Setting Current Detect
Override (S1-1)
Current detect override is used to
disable run-in when a welding pow-
er source is used that doesn't pro-
vide current feedback through the
14-pin receptacle.
.
Pins F & H are not present in 14
pin receptacle on machines
that don't provide current feed-
back.
Install wrapper when finished.
Tools Needed:
1/4 in.
Current Detect Override (OFF)
(Factory Default)
S1-1 And S1-2
Off = Current must be detected
from power sources that provide
current feedback through the
14-pin receptacle to go from run-in
to welding condition. Run-in is
active.
Ref. 805426-B