4-1. Important Information Regarding CE Products (Sold Within The EU)

!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner's Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.

4-2. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.

4-3. Specifications

801 189-C

4-4. Coolant Chart

Application
Coolant
*HF: High Frequency Current
**Coolants 043 810 and 043 809 protect to -37
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts
that come in contact with the coolant (pump, radiator, etc.).
OM-248 626 Page 6
SECTION 4 − SPECIFICATIONS
Recirculating Coolant System For Water-Cooled GTAW Torches, GMAW Guns, And Induction Heaters
Use With Guns/Torches Rated Up To 600 Amperes
IP Rating: 23
3 gal (11.4 L) Coolant Tank Capacity;
Maximum Cooling Capacity: 14,000 BTU/hr At 1.25 qt/min (1.2 L/min)
Dimensions: 23 in. (584 mm) Long, 12 in. (305 mm) Wide, 13-1/4 in. (337 mm) High
Weight: 39 lb (18 kg)
115 Volt Model Use 5.9 Amperes, 50/60 Hertz, Single-Phase Input Power
230 Volt CE Model Use 3 Amperes, 50/60 Hertz, Single-Phase Input Power
Ratings Developed At An Ambient Temperature Of 68F to 77 F (20 C To 25 C)
Operating Temperature Is 14 F To 104 F (−10 C To 40 C)
GTAW Or Where
HF* Is Used
Low Conductivity Coolant
No. 043 810**;
Distilled Or Deionized Water
OK Above 32
F (0
C)
F (-38
C) and resist algae growth.
GMAW Or Where
HF* Is Not Used
Low Conductivity Coolant
No. 043 810**; Or
Aluminum Protecting Coolant
No. 043 809**;
Distilled Or Deionized Water
OK Above 32
F (0
C)
ce-emf 1 2010-10
Where Coolant Contacts
Aluminum Parts
Aluminum Protecting