Miller XMT 304 Manuel du propriétaire - Page 25
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Miller XMT 304. Miller XMT 304 37 pages. 4-rack and 6-rack
Également pour Miller XMT 304 : Manuel du propriétaire (40 pages), Manuel du propriétaire (26 pages)
4-4.
Lift-Arc
Trigger
Hold TIG
~ir~i
1
TIG Electrode
2
Workpiece
2
U~ Procedure
requires:
f~
~3
control
Start sequence:
Touch
tungsten
electrode
to
workpiece
at weld start
point.
Momentarily
depress
output
switch.
Slowly
lift electrode. An
arc
will
form when
electrode is lifted.
To
stop welding,
momentarily
depress
output
switch and
out
put
will shut off.
Note: If
output
switch is
momen
tarily depressed
and
tungsten
is
not
touching workpiece:
Do NOT Strike Like A Match!
Do not touch
tungsten
to
work.
Output
will shut off in 3 seconds.
Start sequence
over.
Ref.
S-i
56 279
OM-193 084
Page
21