A. Power Supply
Input
Rated AC Phase and line fre-
quency (Hz)
Rated Input Voltage (U
) and
1
rated Input Current (I
) and I
1
eff at rated output. I
eff used
1
to determine power cord rating
Power Factor/kVA/kW at Rated
Output
Peak kW at Arc Stretch
Output
Rated Open Circuit Voltage
(U
) Type
0
Output Characteristic
Rated Output Current and Volt-
age (I
, U
) at rated Input Volt-
2
2
age (U
)
1
Output Current Range
Duty Cycle at 104°F (40°C) and
Rated Conditions (U
, I
, U
, I
1
1
2
based on a 10 minute period
General
Toppling or Tilting
Weight
OM-253555 Page 12
Complete Parts List is available at www.MillerWelds.com
Volts AC RMS - (U
1
120 VAC, 1-Phase (20 A)
120 VAC, 1-Phase (15 A)
240 VAC, 1-Phase
Volts AC RMS - (U
120 VAC, 1-Phase (20 A)
120 VAC, 1-Phase (15 A)
240 VAC, 1-Phase
Volts AC RMS – (U
120 VAC, 1-Phase (20 A)
120 VAC, 1-Phase (15 A)
240 VAC, 1-Phase
Volts AC RMS – (U
)
2
120 VAC, 1-Phase (20 A
120 VAC, 1-Phase (15 A)
240 VAC, 1-Phase
240 VAC, 1-Phase
1 - Phase, 50 / 60 Hz
)
Amps RMS - (I
1
26.1
18.3
14.7
)
Power Factor
1
0.994
0.992
0.978
7.0 kW
400 Volts DC/Electrode Negative
Constant Current
)
Amps DC – (I
1
27 A
20 A
30 A
15 - 30 A
)
Amps DC – (I
1
27 A
20 A
30 A
23 A
Up to 15° Incline
18 lb (8.2 kg) Including Torch
)
I
eff
1
1
17.6
14.1
10.5
kVA/kW
3.13/3.11
2.12/2.11
3.53/3.45
)
Volts DC – (U
2
92 V
88 V
92 V
)
Duty Cycle %
2
35%
60%
40%
100%
)