Miller SUITCASE 12RC Manuel du propriétaire - Page 24
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Miller SUITCASE 12RC. Miller SUITCASE 12RC 40 pages. Wire feeder with gun and meters
Également pour Miller SUITCASE 12RC : Spécifications (2 pages), Manuel du propriétaire (36 pages), Manuel du propriétaire (40 pages)
6-3. Setting DIP Switches For Timer Models
DIP SWITCH SETTINGS
Set DIP Switch S1 on PC50 for desired operation.
.
Showing DIP switch setting as
Factory default settings:
OPEN
1
2
3
4
5
Preflow settings:
OPEN
6
1
2
3
4
5
3 Sec Preflow
Burnback settings:
OPEN
6
1
2
3
4
5
Long Burnback
(0.140 Sec)
Postflow settings:
OPEN
6
1
2
3
4
5
5 Sec Postflow
ReTrigger settings:
OPEN
6
1
2
3
4
5
Re−Trigger Enabled
With Re-Trigger enabled: If trigger is pulled within 3 seconds of trigger release, feeder will skip Preflow and go directly to Weld portion
of the weld sequence. If trigger is pulled after 3 seconds, feeder will go directly to Preflow portion of the weld sequence.
OPERATION
The normal weld sequence for this feeder is: pull trigger, feeder goes into 1.5 seconds of preflow, after preflow feeder will be in weld,
release trigger, feeder will be in 5 seconds of postflow. However, the preflow portion of the sequence will be skipped, if the feeder is
re-triggered within 3 seconds of releasing the trigger. If more than 3 seconds passes before the feeder is re-triggered, the feeder weld
sequence starts with 1.5 seconds of preflow.
OM-263984 Page 20
indicates it has no affect on that particular function.
3 Sec Preflow
No BurnBack
5 Sec Postflow
6
7
8
Re−Trigger Enabled
OPEN
7
8
6
7
8
1
2
3
4
5
1.5 Sec Preflow
OPEN
7
8
6
7
8
1
2
3
4
5
Medium Burnback
(0.110 Sec)
OPEN
7
8
6
7
8
1
2
3
4
5
Postflow Disabled
OPEN
7
8
6
7
8
1
2
3
4
5
Re−Trigger Disabled
OPEN
6
7
8
1
2
3
4
5
1
2
3
0.5 Sec Preflow
Preflow Disabled
OPEN
6
7
8
1
2
3
4
5
1
2
3
Burnback Disabled
Short Burnback
(0.081 Sec)
OPEN
6
7
8
4
5
OPEN
6
7
8
4
5