Miller MC-80 Manuel du propriétaire - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Miller MC-80. Miller MC-80 20 pages.

3-2. Installing Machine-Held Torch And Remote Trigger Pendant

WARNING
ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Turn Off cutter, and disconnect input power before
installing torch.
MOVING PARTS can cause injury.
Keep away from moving parts.
Significant DC voltage can remain on capacitors in cutter
after unit is Off. Always discharge capacitors according to
cutter's Owner's Manual before installing torch.
Rear Panel
Tools Needed:
3/8, 5/8 in
Figure 3-2. Installing Machine-Held Torch And Remote Trigger Pendant Into Cutter
OM-1592 Page 4
All manuals and user guides at all-guides.com
5
3
8
HOT PARTS can cause severe burns.
Allow cooling period before maintaining or servicing.
9
4
6
1
5
9
3
4
7
6
2
1
swarn8.1* 10/91
Machine-held torches require a
customer-supplied external switch
or remote trigger control.
Turn Off cutter and remove input
power. Remove top of cutter case.
1
Remote Trigger Leads
2
Strain Relief
3
Boot
Install strain relief in location
shown. Insert leads through boot
and install in strain relief as shown.
Be sure insulation jacket is in strain
relief.
4
Torch Connection Receptacle
5
Gas Hose
6
Pilot Lead
Insert receptacle, hose, and lead
through boot.
7
Pilot Terminal
Connect pilot lead to terminal, and
gas hose to fitting as shown.
8
Printed Circuit Board PC3
9
Three-Way Connector
Connect three-way connector to
matching receptacle on PC3, torch
connection receptacle, and remote
trigger receptacle.
Reinstall top of case.
ST-801 208 / ST-801 202