• Underneath the sink, put plastic (5) and metal
(6) lock washers on the thread bushing and
screw on the fastening nut (7);
• Put on the captive-nut (9) on the plastic pipe
(10) with pressed metal bushing (8) (fig. 8) and
screw on the nut onto the tail end of the faucet.
ATTENTION!
• When you replace the original tap with a dif-
ferent one, there may be noise when you open
it, and clean water flow reduction from the tap
may occur.
• When you replace the original pipes with the
longer ones, there may be noise and clean
water flow reduction from the tap.
• If the water filter has not been used for a long
time, the valves may turn on, making short-term
noise. It is not a sign of the system malfunction.
• Open the clean water tap fully when you use
the water filter, otherwise noise may occur. It
is not a sign of the water filter malfunction.
Figure 8. Tube connecting to the clean water faucet
procedure
11
2
3
4
5
6
7
8
9
10
Ø12
7. Drain saddle installation
Figure 9a. Drain saddle components
1
3
2
It is best install the drain saddle on the sink drain
before the siphon trap or bend (the drain saddle
on most drain pipes is of ~ 40 mm diameter).
1. Apply the part of the collar with the fitting to
the pipe to determine the optimal position of
the collar and the pipe hole.
2. Drill a 7 mm hole in the planned tube location
on the tube pipe.
3. Remove the cut circle from the sealing
gasket (1).
4. Remove the protective tape (2) from the seal-
ing gasket (1). Place the sealing gasket (1) on
the collar inner side, so that the hole in the
gasket meets the hole in the collar fitting.
5. Install the collar onto the pipe, carefully align-
ing the hole in the fitting with the drilled hole;
tighten the bolts (3). The bolts must be tight-
ened evenly in such a way that the two parts
of the collar are located in parallel.
6. Put the plastic nut onto the JG drain tube (1/4",
black) so that the tube is protruding from the
other side of the nut by a length of 20 mm
(see figure 9b).
To eliminate any noise from the water in the drain
saddle, push the JG tube deeper into the pipe.
Figure 9b. Drain saddle installation