After replacing K1 and K2
filter cartridges of the water
treatment unit
• Open the inlet cock of the connecting assembly.
The flashing indicators of the K1 and / or K2
cartridges of the water treatment unit are
followed by a sound signal. The other indicators
are solid.
• Make sure the RO-206S connections are tight.
• On the front panel, flash the PUSH button
3  times to start the flushing mode of the
water pre-treatment unit. At this, 5 audible
signals sound, the indicator lights go out and
the flushing mode of the pre-treatment unit
starts and lasts 30 minutes.
• After flushing procedure is complete, your
RO-206S beeps 5 times and switches into
the operating mode automatically: filtration
and filling the tank with water, while the light
indicators of the pre-treatment unit flash (the
light signal is followed by a sound), the other
indicators are solid.
• Press and hold the PUSH button for at least
7 seconds to reset the cartridge life. The light
indication of the pre-treatment unit changes
from the flashing mode to the constant one,
and the audio signal stops.
to additional tank
Fig. 16
* The whole flushing procedure of the membrane cartridge takes no more than 24 hours and depends on its storage and trans-
portation conditions.
to the tap for clean water
After replacing
the membrane unit:
• Open the inlet cock of the connecting assembly.
The cartridge life light indicators turn on, the
flashing light indicator of the reverse osmosis
membrane unit is followed by a sound signal.
• Make sure the RO-206S connections are tight.
• Let the water through your RO-206S for 1 hour
• Close the treated water tap.
• Press and hold the PUSH button for at least
7 seconds to reset the cartridge life. The light
indication of the reverse osmosis membrane
unit changes from the flashing mode to the
constant one, and the audio signal stops.
ATTENTION! Do not disconnect your RO-206S
from the power supply when in the flushing
mode. Otherwise, the flushing process must
be repeated.
8. Storage Tank
Maintenance
Empty the tank before use if you have not used
the RO-206S for more than 2 days.
Empty and refill the tank 3 times for flushing
before use if you have not used the system for
more than 2 weeks.
Then, you can use the RO-206S again.
ATTENTION! It is recommended to flush the
storage tank with a disinfectant solution at least
1 time a year.
9. Connection
of additional equipment
The ability to connect additional equipment (ice
machine, coffee machine, etc.) depends on the
equipment`s requirements for the source water
and the characteristics of the water at the inlet
to the water purifier. If you need to connect
additional equipment, please contact the service
of the company «AQUAPHOR» or regional dealers
of the company «AQUAPHOR» for advice.
.
*