AQUAPHOR S550 P1 Manuel d'utilisation - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} AQUAPHOR S550 P1. AQUAPHOR S550 P1 20 pages.

AQUAPHOR S550 P1 Manuel d'utilisation

Bypass valve

The softener is equipped with a bypass valve (fig. 1). The
bypass valve will allow you to turn off the softener in the
event of a malfunction or leakage. It also makes it possi-
ble to use untreated water for watering plants.
The bypass valve is located in the main control valve as-
sembly. To switch to the bypass line, turn the valve handle
to the "Bypass"
position (fig. 1). Water will enter the
house past the softener, without treatment. To prevent
untreated water from entering the house, do not use the
water in the house when the softener is in Bypass mode.
Do not forget to switch the softener to normal operation
(filtration) by turning the knob to the "Service"
tion (fig. 1), after repairing the device or using untreated
water.
To obtain water of comfortable hardness, you can use the
scheme shown in fig. 5, mixing the source water with
purified water.
NOTE: It is not recommended to use source water admix-
ture with high content of iron and/or manganese.
Figure 1
In
In

Controller

The controller has four control buttons, LCD display (fig.
2). The controller controls the valve actuators during re-
generation. Using the control panel of the controller, the
6
posi-
Out
Out
value of the compensated hardness, the current time, the
regeneration time are entered and the parameters of the
softener are selected, as well as the status of the device
is viewed. For the filter to work correctly, the controller
must be configured correctly.
The controller receives data on water consumption from
the flow meter. Based on these data and the selected
operating parameters, the controller starts the regener-
ation of the softener at the appointed time.
The controller saves settings in non-volatile memory even
after a power outage.
The controller is equipped with a non-volatile power sup-
ply that allows for two days to maintain the built-in timer.
Figure 2

Control buttons

User Settings.
Change user settings.
Start regeneration manually. It is used
when the softener is connected for the
first time or for forced regeneration, for
example, if the softener runs out of salt.
Start regeneration manually.
1. Press and hold the button
2. The softener will start regenerating and will display the
current stage of regeneration on the display.
3. After all regeneration steps have been completed, the
display will return to normal operating mode.
for about 5 seconds.