3. BMB4 CLOCKING
There are 3 ways to clock the B80 MOTHERSHIP:
BMB4 set to Internal Clock, External Clock, or Sound Grid
3.1 Clocking BMB4 To Internal Word Clock
1.
Set BMB4 front panel to INT.
2.
Push "Sample Rate" button on BMB4 faceplate to toggle to the
desired sample rate.
3.
Open SoundGrid Studio, select SETUP.
4.
Set SoundGrid sample rate to "SLAVE" (Image 24).
5.
In SoundGrid Studio, open MOTHERSHIP GUI by clicking on the gear box in the lower
left corner (Image 25).
6.
Set Source to "B80 Control". Soundgrid Studio and GUI sample rates should both
change to follow the B80 (Image 26).
5
Image 25: Open GUI Settings.
NOTE: The MOTHERSHIP will always default to 96k when powered on.
You must manually change the sample rate on the BMB4 front panel.
SECTION 3
Image 24: SoundGrid Studio set to "SLAVE".
3
6
Image 26: Set B80 GUI Source to
"B80 Control".
11
SoundGrid