Diamond F200 T Manuel - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Diamond F200 T. Diamond F200 T 12 pages.
Remove all the containers that may be in the display cabinet.
Use a soft damp cloth and then dry.
To clean the stainless steel do not use iron wool, iron brushes or scrapers since they can
deposit ferrous particles that by oxidizing lead to rust. To remove hardened residues, use
wooden or plastic spatulas, or stainless steel wool.
If you use alkaline detergents, thoroughly rinse after washing.
Do not spray with direct jets of water or with high-pressure equipment since any water getting
into the outer casing can jeopardize the safety of the machine.
Clean the condenser (see § 7.2.1) at least every six months with a soft brush or with a vacuum
cleaner.
When the appliance has not to be used for long periods, disconnect the electrical power supply,
spread a protective film all over the stainless steel surfaces by passing over them a cloth
soaked in Vaseline oil, and air the rooms periodically.
7.2 Special maintenance
The special maintenance procedures should be carried out by qualified and authorized personnel,
possibly by means of the technical service of the manufacturer of the component requiring
servicing.
CAUTION: it is recommended to use only genuine spare parts, in compliance with the same
technical specifications as the ones replaced.
CAUTION: in any case, before starting, the electrical power supply must be
disconnected by deactivating the automatic switch located up-line from the appliance.
7.2.1 Replacing the refrigerating unit
To access the refrigerating unit it is necessary to carry out the following operations:
1. Make sure you have disconnected the electrical power supply.
2. Remove the top covering by extracting it upwards and taking care over the electrical cables.
3. Remove the insulating cover by unscrewing the four screws.
4. Replace the damaged part of the unit and close it all back up.
7.2.2 Replacing the switch
To replace the switch it is necessary to carry out the following operations:
1. Make sure you have disconnected the electrical power supply.
2. Remove the upper cover by unscrewing the two fixing screws.
3. Replace the switch and close it all back up.
7.2.3 Replacing the thermostat
To replace the thermostat it is necessary to carry out the following operations:
1. Make sure you have disconnected the electrical power supply.
2. Remove the upper cover by unscrewing the two fixing screws.
3. Remove the insulating cover by unscrewing the four screws.
4. Replace the thermostat positioning the sensor in the same position and close it all back up.
7.2.4 Replacing the thermometer
To replace the thermometer it is necessary to carry out the following operations:
1. Make sure you have disconnected the electrical power supply.
2. Remove the upper cover by unscrewing the two fixing screws.
Page 8 of 11