Burlington AF1S Manuel d'instructions d'installation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Burlington AF1S. Burlington AF1S 6 pages. Avon thermostatic exposed shower valve outlet with fixed shower arm

Operation

1. Turn the water flow control handle to increase/decrease
the water flow and turn on/off.
2. Turn the temperature control handle to increase/decrease
the water temperature.
3. The temperature control knob is pre-set the auto stop at 42°C to
avoid scalding.
However, if for any reason the setting is removed it is important to
follow "Temperature Setting" procedure to reset.

Temperature Setting

The temperature control handles on this product are factory set and should require no adjustment.
However, if for any reason the handles and/or the cartridge is removed it is important the following procedure is followed.
A) Turn flow control handle to maximum flow position, and
temperature control handle anti-clockwise until it contacts
the internal limit stop.
B) Allow the water temperature to stabilize around 3 minutes
and check the temperature by thermometer.
C) Proceed if temperature is not 42°C.
SPINDLE
A) Temporarily refit the metal block until it just engages on
the splines of the spindle.
B) Turn on the water.
C) Slowly turn the metal block in the required direction until
the discharge temperature is achieved.
D) Remove the metal block when finished.
Maintenance (Thermostatic Cartridge)
* After a long time usage of thermostatic valve, there will be some waste debris from the water pipe on and around the thermostatic cartridge,
which will affect the flow and sensitivity of automatical temperature adjustment. Please take out the thermostatic cartridge, and clean the
cartridge strainer
* To avoid damage, please remove all chrome parts before any maintenance takes place.
A) Remove the cartridge cap, ceramic ring and metal block (see Fig. 1).
B) Remove the metal ring, plastic block and cartridge clamp nut (see Fig. 2).
C) Pull out the cartridge together with location lug (see Fig. 3).
D) Wash the cartridge with clean running water, dry and lightly grease the seals (only use silicone grease) (See Fig. 4).
E) Replace the cartridge and make sure it back to the primary position.
* Cartridge Type: " SP32 " is the spare part number of thermostatic cartridge.
FLOW CONTROL
TEMPERATURE
CONTROL
1
A) Turn off the water
B) Unscrew the decorative cap on the temperature control handle.
C) Unscrew and remove the handle.
D) Unscrew and remove the cartridge cap.
E) Pull off the metal block with limit stop on the backside.
METAL BLOCK
3
A) Without rotating the temperature spindle, replace the
B) Refit and tighten the cartridge cap and screw.
WATER FLOW
CONTROL
TEMPERATURE
CONTROL
METAL BLOCK
CERAMIC
RING
CARTRIDGE CAP
HANDLE
METAL BLOCK
LIMIT STOP
metal block so that limit stop inside metal block up to
the right hand side of the limit stop on the plastic block.
Refit and tighten the decorative cap.
4 - 5
OFF
ON
COLD
HOT
LIMIT STOP
DECORATIVE
CAP
2
CERAMIC RING
CARTRIDGE CAP
4
B