INSTALLATION OF SENSORS

On the upper side of the storage tank there are two sensor tubes for mounting the sensors for regulation of the system connection
of the hot water storage tank to other heating sources. The maximum diameter of the sensors is 8 mm.
Image 5: Installation of sensors
WARNING: Before any intervention into the interior of the storage tank disconnect it from the power supply! All
interventions must be carried out by qualified staff only!
WATER HEATER ASSEMBLY AND CONNECTION
Before connecting to power supply network, install a power supply cord in the storage tank, with a min. diameter of at least
1.5 mm
(H05VV-F 3G 1.5 mm
2
thermostat axis and unscrewing two screws.
An all-pole disconnect device must be installed in the electric installation to comply with the National Installation Regulations.
Image 6: Water heater assembly
Long sensor tube (lower tank position)
Short sensor tube (upper tank position)
). To do so, the protection cover must be removed. This is done by pulling out the knob on the
2